AC Blowing Warm Air But Outside Unit Running

Your house feels incredibly hot on a sunny summer day. You walk over to your wall and turn the cooling system on. You feel the air coming from your ceiling vents. The air feels completely warm instead of freezing cold. You walk outside and see the big metal machine running perfectly. We will explain why you have an ac blowing warm air but outside unit running today.

Why The Machine Fails

Checking The Paper Filter

Your cooling machine needs a massive amount of room air to work. A dirty paper filter blocks this air from reaching the cold metal parts. The metal coils get completely confused without the warm room air. This makes the machine blow hot air back into your face. You must change your paper filter every single month to stop this. Read our Master Your Furnace Filter Direction Arrow & MERV Ratings Guide to do this fast.

A Frozen Indoor Coil

A clogged filter causes a massive chain reaction inside the metal box. The indoor metal coil drops below freezing very quickly. The water in the air turns into solid white ice on the metal. This thick ice blocks all the cold air from reaching your rooms. You will only feel warm air blowing from the vents. You must turn the machine off to let the ice melt.

Need Fast Cooling Help?

Is your house extremely hot right now? Do you need a trained worker to fix your broken machine today? Our team can find the hidden mechanical problem very fast.

Expanded Electrical Parts And Costs

System ComponentMain PurposeExpected LifespanEstimated Part CostEstimated Labor Cost
Dual Run CapacitorStarts the main compressorFive to ten years$20 to $40$150 to $200
Paper Air FilterLets the machine breatheOne single month$10 to $20Free to do yourself
Chemical RechargeFills the empty copper pipesFive to ten years$100 to $300$150 to $300
Outdoor Fan MotorPulls hot air out of the boxTen to fifteen years$150 to $300$300 to $500
Compressor PumpMoves the cooling chemicalsTwelve to twenty years$800 to $1500$1500 to $2500

Finding Hidden Electrical Problems

A Dead Compressor Pump

The outdoor machine has two different heavy motors inside the metal box. The top fan blows hot air away from the metal coils. The hidden compressor pump moves the cold chemicals through the copper pipes. The top fan can spin perfectly while the hidden pump sits completely dead. The system cannot cool your house without the hidden pump working. Read our AC Compressor Emergency Repair Guide to learn about this big pump.

The Broken Silver Can

A small silver piece gives the hidden pump its starting electrical power. This small piece looks exactly like a tiny silver soup can. A broken silver can stops the hidden pump from turning on at all. The top fan keeps spinning but the air inside stays totally warm. Check our Bad AC Capacitor Symptoms page to see how this part fails. A professional worker must test this dangerous electrical part safely.

A Digital Testing Tool Resting On An Outdoor Air Conditioner Next To Light Blue Vinyl Siding

Leaking Cooling Chemicals

Tiny Holes In The Pipes

Your cooling machine uses a very special chemical to make cold air. This chemical travels through heavy copper pipes all day long. A tiny hole in the copper pipe lets this expensive chemical leak out. The machine will run all day but never cool your hot house. Check the Energy.gov Air Conditioning site to see how these chemicals work.

Fixing The Hidden Leaks

You cannot buy these freezing chemicals at the local hardware store. Federal laws require a special license to handle these dangerous freezing gases. A professional worker uses a digital tool to find the tiny holes. They use a hot torch to seal the broken copper pipes perfectly. Review HomeAdvisor AC Repair Costs to see local rates for chemical testing.

A Thick Copper Pipe Connected To An Outdoor Cooling Machine Next To Yellow Vinyl Siding

FAQ

Why is my ac blowing warm air but outside unit running constantly?

Your top outdoor fan is simply spinning perfectly fine while the hidden internal compressor pump sits completely dead due to a broken electrical starting part.

Can a dirty air filter cause my indoor ceiling vents to blow hot air?

A completely clogged paper filter blocks the warm room air from reaching the metal coils which causes the entire indoor machine to freeze solid and blow warm air.

How much does a professional worker charge to fix a dead cooling machine?

A licensed professional usually charges between one hundred and two hundred dollars to safely test the dangerous electrical parts and install a brand new silver starting component.

Will my cooling machine fix itself if I just turn the thermostat off?

The solid ice on the indoor coils will naturally melt if you turn the system off for several hours but the machine will immediately freeze again tomorrow if you do not replace the dirty filter.

Why is the outside metal pipe covered in thick white ice right now?

A massive chemical leak drops the pressure inside the copper pipes so fast that the outside moisture instantly turns into solid white ice while the machine runs.

Conclusion

A running outdoor machine does not always mean your system is working properly. You must check your paper filter first to ensure the machine can breathe. A dead internal pump or a chemical leak will leave your house completely hot. Expect to pay about two hundred dollars for a safe professional repair today. Call our expert team to test your dangerous electrical parts safely. Use our HVAC Services page to schedule a fast repair visit right now.

Similar Posts